< Back to Pipe Anchors
Model C4200 - Insulated Positive Pipe Anchor |
Download PDF
Dimensions and ratings are subject to change without notice.
The load ratings represent average values obtained in accordance with accepted test methods and are subjected to normal manufacturing variations.
Note: For higher load ratings, see: C4300. If thrust plate thickness "D" is greater than pipe wall thickness, consult factory.
Installation Instructions
Pipe Size |
Load Rating |
Insul Thk. = 2" |
Insul Thk. = 2-1/2" |
Insul Thk. = 3" |
Insul Thk. = 4" |
Vert. lb. |
Axial lb. |
B |
C |
D |
E |
B |
C |
D |
E |
B |
C |
D |
E |
B |
C |
D |
E |
1
1 1/2 |
600
870
|
900
1290
|
4
4 |
3
4
|
0.3125
0.3125 |
6.687
7.75
|
4
4
|
4
4.5
|
0.3125
0.3125 |
7.75
8.75
|
6
6
|
4.5
5.5
|
0.3125
0.375 |
8.75
9.75
|
6
6
|
6.5
7.5 |
0.3125
0.375 |
10.75
11.875
|
2
2 1/2
3
4 |
1090
1310
1600
2500 |
1620
1960
3450
4100
|
4
4
4
4 |
4
4.5
4.5
5.5 |
0.3125
0.3125
0.375
0.375 |
7.75
8.75
8.75
9.75 |
4
4
4
4 |
4.5
5.5
5.5
6.5 |
0.3125
0.375
0.5
0.5 |
8.75
9.75
9.75
10.75 |
6
6
6
6 |
5.5
6.5
6.5
7.5 |
0.375
0.375
0.5
0.5 |
9.75
10.75
10.75
11.875 |
6
6
6
6 |
7.5
8
8
9 |
0.375
0.375
0.5
0.5 |
11.875
12.875
12.875
13.875 |
5
6
8
10 |
3100
3800
5100
6000 |
4750
5400
6675
8000
|
4
4
4
4 |
6.5
7.5
9
10.5 |
0.375
0.375
0.375
0.375 |
10.75
11.875
13.875
16.375 |
4
4
6
6 |
7.5
8
9.5
11 |
0.5
0.5
0.5
0.5 |
11.875
12.875
15.125
17.375 |
6
6
6
6 |
8
9
10.5
12 |
0.5
0.5
0.5
0.5 |
12.875
13.875
16.125
18.375 |
6
6
6
6 |
9.5
10.5
12
13 |
0.5
0.5
0.5
0.5 |
15.125
16.125
18.125
20.375 |
12
14
16
18 |
6600
7500
8700
9600 |
9300
10000
11300
12500
|
4
4
6
6 |
12
12.5
14
15.5 |
0.375
0.375
0.375
0.375 |
18.375
19.375
21.375
23.375 |
6
6
6
6 |
12.5
13
14.5
16 |
0.5
0.5
0.5
0.5 |
19.375
20.375
22.375
24.375 |
6
6
6
6 |
13
14
15.5
16.5 |
0.5
0.5
0.5
0.5 |
20.375
21.375
23.375
25.375 |
6
6
8
8 |
14.5
15.5
16.5
18 |
0.5
0.5
0.5
0.5 |
22.375
23.375
25.375
27.375 |
20
24
30
36
42 |
10200
10800
14100
16500
16500 |
13800
16300
20100
23900
23900
|
6
6
6
6
6 |
16.5
19.5
24
28
32.5 |
0.375
0.375
0.375
0.375 0.375 |
25.375
29.375
35.625
41.625
47.625 |
6
6
6
6
6 |
17.5
20.5
24.5
28.5
33 |
0.5
0.5
0.5
0.5 0.5
|
26.375
30.375
36.625
42.625
48.625 |
6
6
6
6
6 |
18
21
25
29.5
33.5 |
0.5
0.5
0.5
0.5 0.5 |
27.375
31.375
37.625
43.625
49.625 |
8
8
8
8
8 |
19.5
22.5
26.5
31
35 |
0.5
0.5
0.5
0.5 0.5 |
29.375
33.375
39.625
45.625
51.625 |
|
|
Application:
Models C4200 through C4230 are designed for use on:
- Cold Water
- Hot Water
- Chilled Water
- Dual Temperature
- Steam
- Air
- Gas
- Vacuum
- Where large axial forces must be resisted
Intended for Installation on:
Temperature Range: +40°F to +1200°F |
Features
- All pipe sizes
- Easy Installation
- Overlapping galvanized sheet metal jacket
- Insulating structural inserts for load transfer
- Other I.D.'s and/or O.D.'s available on request
- Bottom-of-pipe to top-of-shield matches insulated supports in "B" series
Performance Test Results on File: Available upon request. |
Material Data:
- C4200 - C4230: Applicable PSI spec. doc.: No. 209
- Steel Inner Thrust Plates (supplied loose):
- Model C4200: A36 Carbon Steel
- Model C4210: A387GR.22 Chrome Moly
- Model C4220: A515GR.70 Carbon Silicon
- Model C4230: A304L Stainless Steel
- Jackets: Galvanized Steel ASTM-527
- Structural Inserts: High-density calcium silicate asbestos-free, treated with water repellant
- Glue: Industrial contact adhesive
- Steel Straps/Base: Carbon Steel ASTM A-36
- Fasteners: ASTM A-307 Plated
- Coating: Primer coated or hot dipped galvanized. Other coatings available upon request.
Formal Submittal Sheets Available |
|
|
|
|
|
|
|
|
|